Technical Note Hydroxyzine: An Analytical Profile Norman
G. Odeneal II,* John F. Casale, and Heidi L. Wojno ABSTRACT: Hydroxyzine, an anxiolytic and antihistamine, was identified as an adulterant in several large shipments of illicit cocaine. Analytical data (gas chromatography, infrared spectroscopy, mass spectrometry, and proton nuclear magnetic resonance spectroscopy) are presented. KEYWORDS: Hydroxyzine, Anxiolytic, Antihistamine, Cocaine, Forensic Chemistry
Introduction This laboratory recently received samples from several multi-kilogram seizures of cocaine hydrochloride containing varying amounts of hydroxyzine (2 - 20 %) (1). The full chemical name for hydroxyzine is 2-[2-[4-[(4-chlorophenyl)phenylmethyl]-1-piperazinyl]ethoxy]ethanol. Hydroxyzine is marketed as an anxiolytic (used in treatment of anxiety), antihistamine (allergy), and as a mild tranquilizer (2,3). It is sold in tablet form. Federal law restricts this drug to prescription use only. Herein, we provide analytical data for hydroxyzine (4). Experimental Hydroxyzine: C21H27ClN2O2 374.91 amu Source
Utilizing the above experimental parameters, the retention time for hydroxyzine is 10.63 minutes. The retention time relative to cocaine is 2.85. Infrared Spectroscopy
The Total Ion Chromatogram (TIC) for hydroxyzine is shown in Figure 3. The fragmentation pattern shows a molecular ion at m/z 374 and a base peak of m/z 201 (Figure 4). Hydroxyzine may also be further characterized by GC/MS after derivatization. Hydroxyzine (5 mg) was reacted with a mixture of 250 µL of N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA) in 250 µL of chloroform at 80° C for 30 minutes. The mass spectrum of the resulting trimethylsilyl (TMS) derivative gives a molecule ion at m/z 446 (Figure 5). Nuclear Magnetic Resonance Spectroscopy Results and Discussion The referenced exhibits appear to be the first identified to contain hydroxyzine. Based on cocaine signature analysis, it appears that the hydroxyzine was added to the cocaine hydrochloride and physically mixed prior to pressing into kilogram bricks. The purpose for adulterating illicit cocaine with such an unusual (and relatively expensive) compound is unclear. A (brief) review of several websites dedicated to drug abuse does not suggest any synergistic/desirable or pseudo-therapeutic effects to co-administration of hydroxyzine with cocaine. Therefore, it is most likely that it was used merely as a “cut of convenience”. Acknowledgements The author wishes to thank Senior Research Chemist Patrick A. Hays (this laboratory) for his time and expertise in interpreting the NMR spectrum of hydroxyzine. References
---------------------------------------
---------------------------------------
---------------------------------------
---------------------------------------
---------------------------------------
Index Page | Next | Previous |