Building 5241, unit 101
Building 3160, units 103, 104
Building 3103, all units
Building 3060, unit 103
Building 3041, units 102, 103, 104
Building 3054, unit 101
Building 3035, all units
Building 3051, all units
Building 3055, unit 103
Building 3063, all units
Building 3058, all units
Building 3067, all units
Building 3136, all units
Building 3056, units 101, 102
Building 3068, unit 104
Building 5235, unit 102
Building 3042, unit 101
Building 3046, all units
Retrofit non-compliant curb ramp in front of this building and provide accessible parking space.
Install compliant curb ramp at two accessible parking spaces between these two buildings.
• Install curb ramp at compliant accessible parking space
serving these two buildings.
• Retrofit non-compliant curb ramp near building 3038 and
provide accessible parking space.
Retrofit curb ramp at accessible parking space between these two buildings on Tarpon.
Install compliant curb ramp at accessible parking space at this building.
• Provide access aisle at standard accessible parking
space near this building and regrade cross slope.
• Regrade cross slope at van accessible parking apace at
this building.
• Remove speed bump.
Retrofit non-compliant curb ramp at accessible space that serves these three buildings.
Provide compliant curb ramp at accessible parking spaces in front of Building 3063 near Key Largo Drive.
Retrofit non-compliant curb ramp that serves these three building.
• Restripe access aisle adjacent to accessible parking
serving these buildings.
• Install compliant curb ramp for the accessible parking
space.
Regrade sloped path leading to this building to make it compliant.
Install compliant curb ramp at two accessible parking spaces between Buildings 3121 and 3131 which would serve all three of these buildings.
Retrofit non-compliant curb ramp at accessible parking space.
Regrade access aisle to compliant slope.
• Provide access aisle for two accessible parking spaces
near units 102 and 104 of Building 5235.
• Retrofit non-compliant curb ramp adjacent to unit 102
of building 5235.
• Provide access aisle for first accessible parking space
which lacks same.
• Retrofit non-compliant curb ramp in access aisle for second accessible parking space.
Provide compliant curb ramp at accessible parking space serving these two buildings.
• Provide access aisle for first accessible parking space
which lacks same.
• Regrade access aisle to make slope compliant.
• Retrofit non-compliant curb ramp.
Retrofit non-compliant curb ramp at accessible parking space near Building 3120 on the north side of the Tarpon East lot.
Retrofit non-compliant ramp at the corner of the walkway in front of this building.
Retrofit curb ramp at accessible parking space serving these two buildings.
• Retrofit non-compliant curb ramp near this Building.
• Remove parking space blocking the curb ramp.
• Install compliant curb ramp at two accessible parking
spaces at this building.
• Regrade sidewalk at this building to compliant slope.
Provide access aisle at accessible parking space at this building.
Club House
Install one van accessible parking space.
Rear Door to Pool Area
Lower threshold to 3/4 inches and bevel.
Rearrange exercise equipment to create an accessible route to the exercise equipment.
• Install lever hardware on lavatory and raise to 29
inches.
• Install horizontal bar at rear of toilet compliant with
ANSI 4.16.4.
• Remount mirror with the bottom edge of the reflecting
surface at 40 inches above the floor.
• Install lever hardware on lavatory and raise to 29 inches.
• Remount mirror with the bottom edge of the reflecting
surface at 40 inches above the floor.
Parking
Provide one accessible parking space.
Path to swimming pool
Regrade slope and cross slope on this path or provide handrails and edge protection.
Gate
• Provide 18 inches of clearance on the pull side of the gate.
• Regrade slope at the gate to be compliant.
Parking
Provide compliant curb ramp at accessible space near Building 3090.
Gate
Provide 18 inches of clearance on the pull side of the gate.
Women's Toilet Room
• Install lever hardware on the entry door.
• Lower entry threshold to 3/4 inches and bevel.
• Install horizontal bar at rear of toilet compliant with
ANSI 4.16.4.
• Remount grab bar on side wall compliant with ANSI
4.16.4.
• Relocate flush control to for use from wide side of the
toilet stall.
• Remount mirror with the bottom edge of the reflecting
surface at 40 inches above the floor.
Men's Toilet Room Door
• Install lever hardware on the entry door.
• Lower entry threshold to 3/4 inches and bevel.
• Install horizontal bar at rear of toilet compliant with
ANSI 4.16.4
• Remount grab bar on side wall compliant with ANSI
4.16.4.
• Remount mirror with the bottom edge of the reflecting
surface at 40 inches above the floor.
Showers
Install lever hardware.
Parking
Provide compliant curb ramp at accessible space at Building 5140.
Gate
Provide 18 inches of clearance on the pull side of the gate.
Women's Toilet Room
• Relocate lavatory to 29 inches above the floor.
• Install horizontal bar at rear of toilet compliant with
ANSI 4.16.4
• Remount grab bar on side wall compliant with ANSI
4.16.4.
• Relocate flush control to for use from wide side of the
toilet stall.
• Relocate toilet paper dispenser to 36 inches from the
rear wall.
• Remount mirror with the bottom edge of the reflecting
surface at 40 inches above the floor.
Men's Toilet Room
• Install horizontal bar at rear of toilet compliant with
ANSI 4.16.4
• Remount grab bar on side wall compliant with ANSI
4.16.4.
• Relocate toilet paper dispenser to 36 inches from the
rear wall.
• Remount mirror with the bottom edge of the reflecting
surface at 40 inches above the floor.
Trash Enclosures
Install lever hardware on door to all trash dumpsters.
1. All retrofits performed to the public use and common areas shall comply with ANSI A117.1.
![]() |
![]() |