Housing And Civil Enforcement Cases Documents
- Eliminate steps on the route to the following units:
Building 5241, unit 101
Building 3160, units 103, 104
Building 3103, all units
Building 3060, unit 103
Building 3041, units 102, 103, 104
Building 3054, unit 101
Building 3035, all units
Building 3051, all units
Building 3055, unit 103
Building 3063, all units
Building 3058, all units
Building 3067, all units
Building 3136, all units
Building 3056, units 101, 102
Building 3068, unit 104
Building 5235, unit 102
Building 3042, unit 101
Building 3046, all units - Building 5196
Retrofit non-compliant curb ramp in front of this building and provide accessible parking space.
- Buildings 5216, 5222
Install compliant curb ramp at two accessible parking spaces between these two buildings.
- Buildings 3038, 3042
 Install curb ramp at compliant accessible parking space serving these two buildings.
 Retrofit non-compliant curb ramp near building 3038 and provide accessible parking space. - Buildings 3046, 3050
Retrofit curb ramp at accessible parking space between these two buildings on Tarpon.
- Building 3041
Install compliant curb ramp at accessible parking space at this building.
- Building 3070
 Provide access aisle at standard accessible parking space near this building and regrade cross slope.
 Regrade cross slope at van accessible parking apace at this building.
 Remove speed bump. - Buildings 5150, 5140, 5130
Retrofit non-compliant curb ramp at accessible space that serves these three buildings.
- Buildings 3044, 3063, 3061
Provide compliant curb ramp at accessible parking spaces in front of Building 3063 near Key Largo Drive.
- Buildings 3058, 3067, 3071
Retrofit non-compliant curb ramp that serves these three building.
- Buildings 3087, 3083
 Restripe access aisle adjacent to accessible parking serving these buildings.
 Install compliant curb ramp for the accessible parking space. - Building 3103
Regrade sloped path leading to this building to make it compliant.
- Buildings 3123, 3131, 3119
Install compliant curb ramp at two accessible parking spaces between Buildings 3121 and 3131 which would serve all three of these buildings.
- Buildings 2060 and 3056
Retrofit non-compliant curb ramp at accessible parking space.
Regrade access aisle to compliant slope.
- Buildings 5235, 5217, 5223, 3225, 3215, 3155, 3145, 3125
 Provide access aisle for two accessible parking spaces near units 102 and 104 of Building 5235.
 Retrofit non-compliant curb ramp adjacent to unit 102 of building 5235. - Buildings 3115, 3105, 3101
 Provide access aisle for first accessible parking space which lacks same.
 Retrofit non-compliant curb ramp in access aisle for second accessible parking space. - Buildings 3190, 3182
Provide compliant curb ramp at accessible parking space serving these two buildings.
- Buildings 3066, 3068, 3074, 3062
 Provide access aisle for first accessible parking space which lacks same.
 Regrade access aisle to make slope compliant.
 Retrofit non-compliant curb ramp. - Buildings 3104, 3120
Retrofit non-compliant curb ramp at accessible parking space near Building 3120 on the north side of the Tarpon East lot.
- Building 3136
Retrofit non-compliant ramp at the corner of the walkway in front of this building.
- Buildings 3078, 3090
Retrofit curb ramp at accessible parking space serving these two buildings.
- Building 3174
 Retrofit non-compliant curb ramp near this Building.
 Remove parking space blocking the curb ramp. - Building 3053
 Install compliant curb ramp at two accessible parking spaces at this building.
 Regrade sidewalk at this building to compliant slope. - Building 3035
Provide access aisle at accessible parking space at this building.
Club House
- Parking
Install one van accessible parking space.
- Doors
Rear Door to Pool Area
Lower threshold to 3/4 inches and bevel.
- Accessible Route to Exercise Room
Rearrange exercise equipment to create an accessible route to the exercise equipment.
- Women's Toilet Room in Club House
 Install lever hardware on lavatory and raise to 29 inches.
 Install horizontal bar at rear of toilet compliant with ANSI 4.16.4.
 Remount mirror with the bottom edge of the reflecting surface at 40 inches above the floor. - Men's Toilet Room in Club House
 Install lever hardware on lavatory and raise to 29 inches.
 Remount mirror with the bottom edge of the reflecting surface at 40 inches above the floor. - Pool #1
Parking
Provide one accessible parking space.
Path to swimming pool
Regrade slope and cross slope on this path or provide handrails and edge protection.
Gate
 Provide 18 inches of clearance on the pull side of the gate.
 Regrade slope at the gate to be compliant. - Pool #2
Parking
Provide compliant curb ramp at accessible space near Building 3090.
Gate
Provide 18 inches of clearance on the pull side of the gate.
Women's Toilet Room
 Install lever hardware on the entry door.
 Lower entry threshold to 3/4 inches and bevel.
 Install horizontal bar at rear of toilet compliant with ANSI 4.16.4.
 Remount grab bar on side wall compliant with ANSI 4.16.4.
 Relocate flush control to for use from wide side of the toilet stall.
 Remount mirror with the bottom edge of the reflecting surface at 40 inches above the floor.Men's Toilet Room Door
 Install lever hardware on the entry door.
 Lower entry threshold to 3/4 inches and bevel.
 Install horizontal bar at rear of toilet compliant with ANSI 4.16.4
 Remount grab bar on side wall compliant with ANSI 4.16.4.
 Remount mirror with the bottom edge of the reflecting surface at 40 inches above the floor.Showers
Install lever hardware.
- Pool #3
Parking
Provide compliant curb ramp at accessible space at Building 5140.
Gate
Provide 18 inches of clearance on the pull side of the gate.
Women's Toilet Room
 Relocate lavatory to 29 inches above the floor.
 Install horizontal bar at rear of toilet compliant with ANSI 4.16.4
 Remount grab bar on side wall compliant with ANSI 4.16.4.
 Relocate flush control to for use from wide side of the toilet stall.
 Relocate toilet paper dispenser to 36 inches from the rear wall.
 Remount mirror with the bottom edge of the reflecting surface at 40 inches above the floor.Men's Toilet Room
 Install horizontal bar at rear of toilet compliant with ANSI 4.16.4
 Remount grab bar on side wall compliant with ANSI 4.16.4.
 Relocate toilet paper dispenser to 36 inches from the rear wall.
 Remount mirror with the bottom edge of the reflecting surface at 40 inches above the floor.Trash Enclosures
Install lever hardware on door to all trash dumpsters.
1. All retrofits performed to the public use and common areas shall comply with ANSI A117.1.
Document Entered: January 12, 2004 > >